Experimental class on“Fuel Cell and Electrochemistry”

Experiment setup

Equipment: CHI760D electrochemical station

Three electrode system. WE: CE: RE: Saturated Calomel Electrode Solution: 1.0 ×10-3mol/L K3 [ Fe (CN)6] + 0.1M KCl

Lab report

1) Plot curves of LSV curve, and describe why current changes with sweeping voltage?

0.000010

0.000008

0.000006

Current/uA

0.000004

0.000002

0.000000

0.6

0.4

0.2

0.0

-0.2

-0.4

Potential/V

oltage is a driving force to an electrode reactions, it is concerned with the equilibrium

of electron transfer at electrode surface. As the altering of applied voltage, the Fermi-level is raised (or lowered), which changing the energy state of the electrons. Making the overall barrier height (ie activation energy) alter as a function of the applied voltage.

(1). In this reaction, when voltage is 0.6V, there is no electron transfer, so the current is zero.

With the voltage to the more reductive values, the current increases.

(2). When the diffusion layer has grown sufficiently above the electrode so that the flux of reactant to the electrode is not fast enough to satisfy that required by Nernst Equation. The peak is obtaining. (3). When the reaction continued, it would get a situation that there will be a lower reactant concentration at the electrode than in bulk solution, that is, the supply of fresh reactant to the surface decreased, so current decreases.

2) Plot the curves of CV curves with different scan rate;

Current/A

0.6

0.4

0.2

0.0

-0.2

-0.4

Potential/V

3) From the CV curves, fill the table

4) According to the result, describe why curves shows certain trend, and how peak current

and peak voltage difference change with scan rate?

From above data and curve, we can obtain:

A. At a fixed scan rate : (1).from initial positive voltage to more reductive values, the current begin

to flow, then reach a peak ipc and decrease eventually. (2).when voltage moves back, the

2+3+

equilibrium positions gradually converting electrolysis product (Fe) back to reactant (Fe), the current flow is from the solution species back to the electrode and so occurs in the opposite

sense to the forward. The process has another current peak ipa. It has same reason of linear sweep voltammetry.

B. At different scan rate, the ratio of peak current ipc/ipa is about equal to 1 (1.009—1.043). C. At different scan rate, the position of peak voltage do not alter greatly ΔEp is about a

constant (66--79).

(1) Ip--V1/2

50

40

30

Ip/uA

2010

51015202530

v1/2/(mV/s)1/2

Figure 1: Peak current VS radical sign of scan rate

It is apparent that the peak current is linear to radical sign of scan rate, which

1/2

satisfy this equation: ip = kvC0.

Reason:This can be rationalised by considering the size of the diffusion layer and the time taken to record the scan. Clearly the linear sweep voltammogram will take longer to record as the scan rate is decreased. Therefore the size of the diffusion layer above the electrode surface will be different depending upon the voltage scan rate used. In a slow voltage scan the diffusion layer will grow much further from the electrode in comparison to a fast scan. Consequently the flux to the electrode surface is considerably smaller at slow scan rates than it is at faster rates. As the current is

proportional to the flux towards the electrode, the magnitude of the current will be lower at slow scan rates and higher at high rates.

(2) Ep--V

(3) Ep’--v

)

V( pE0100200300400500600700

v(mV/s)

Figure 2: Peak potential VS scan rate

160

120

Ep'(mV)

80

40

0v (mV/s)

Figure 3: the change of Peak potential VS scan rate

Figure 3: shows the Peak voltage difference is constant in different scan rate.

The characteristic of this electrode reaction has rapid electron transfer kinetics and there is no charge transfer in double layer, so this reaction is reversible.

…… 此处隐藏:1823字,全部文档内容请下载后查看。喜欢就下载吧 ……
电化学实验报告实验报告.doc 将本文的Word文档下载到电脑,方便复制、编辑、收藏和打印
本文链接:https://www.jiaowen.net/wenku/47064.html(转载请注明文章来源)
Copyright © 2020-2025 教文网 版权所有
声明 :本网站尊重并保护知识产权,根据《信息网络传播权保护条例》,如果我们转载的作品侵犯了您的权利,请在一个月内通知我们,我们会及时删除。